Easytop concealed free flow valve with SC‑Contur
for drinking water installation
Year built (from): | 12.05.2010 |
Trade mark rights exist for this document; for further information, go to viega.com/legal .
The information in this manual is directed at heating and sanitary professionals and trained personnel.
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe and are provided as a support feature.
Scope / Notice | Regulations applicable in Germany |
---|---|
Planning, execution, operation and maintenance of potable water installations | DIN EN 806, part 1 |
Planning, execution, operation and maintenance of potable water installations | DIN EN 806, part 2 |
Planning, execution, operation and maintenance of potable water installations | DIN EN 806, part 3 |
Planning, execution, operation and maintenance of potable water installations | DIN EN 806, part 4 |
Planning, execution, operation and maintenance of potable water installations | DIN EN 806, part 5 |
Planning, execution, operation and maintenance of potable water installations | DIN EN 1717 |
Planning, execution, operation and maintenance of potable water installations | DIN 1988 |
Planning, execution, operation and maintenance of potable water installations | VDI/DVGW 6023 |
Planning, execution, operation and maintenance of potable water installations | Trinkwasserverordnung (TrinkwV) |
Scope / Notice | Regulations applicable in Germany |
---|---|
Suitability for drinking water | Trinkwasserverordnung (TrinkwV) |
Scope / Notice | Regulations applicable in Germany |
---|---|
Suitability for drinking water installations | Trinkwasserverordnung (TrinkwV) |
Suitability for drinking water installations | DIN 50930‑6 |
Requirements in plastic components in drinking water installations | DVGW-Arbeitsblatt W270 |
Scope / Notice | Regulations applicable in Germany |
---|---|
Compliance with the inspection requirements (fittings group I) | DIN EN 13828 |
Compliance with the inspection requirements (fittings group I) | DIN EN 1213 |
Scope / Notice | Regulations applicable in Germany |
---|---|
Designation noise class I | DIN EN 1213 DIN EN 13828 |
Scope / Notice | Regulations applicable in Germany |
---|---|
External corrosion protection | DIN EN 806‑2 |
External corrosion protection | DIN 1988‑200 |
External corrosion protection | DKI-Informationsdruck i. 160 |
Scope / Notice | Regulations applicable in Germany |
---|---|
Leakage test for potable water installations | DIN EN 806, part 4 |
Leakage test for potable water installations | ZVSHK-Merkblatt |
Scope / Notice | Regulations applicable in Germany |
---|---|
Operation and maintenance of potable water installations | DIN EN 806‑5 |
Coordinate the use of the model for areas of use and media other than those described with the Viega Service Center.
Use is possible in the following areas among others:
Drinking water installations
– with Raxofix PE‑Xc/AI/PE‑Xc pipes (dimensionally stable, with external oxygen seal coat)
– with Raxofix PE‑Xc pipes (flexible without external oxygen seal coat)
The model serves as a shut-off for the storey units.
The general rules of engineering and the applicable regulations must be observed for planning, execution, operation and maintenance potable water installations, see Regulations from section: Fields of application .
The model is also suitable for the following media, amongst others:
Drinking water without limitations acc. to the applicable directives, see Regulations from section: Media
maximum chloride concentration 250 mg/l pursuant to applicable regulations, see Regulations from section: Media
According to the applicable regulations, Easytop system fittings can be used for all types of potable water and are DVGW certified, see Regulations from section: Product description . Their plastic components comply with the KTW recommendation and the requirements pursuant to the applicable regulations.
The Easytop system fittings comply with the test requirements specified in the applicable regulations, see Regulations from section: Overview Sound protection Lap≤ 20 dB(A)
The model is equipped as follows:
all parts that come into contact with water are made of gunmetal/silicon bronze
top
Site protection
dual-sided Raxofix press connection with SC‑Contur
green dot for potable water
The model is available in the following dimensions: d 16 / 20 / 25.
Viega press connections are equipped with the SC‑Contur. The SC‑Contur is a safety technology that is certified by the DVGW and ensures that the connection is guaranteed to be leaky in an unpressed state. In this way, unpressed connections are noticed immediately during a leakage test.
Viega guarantees that unpressed connections are visible during a leakage test:
with wet leakage test in the pressure range from 0.1 hPa–0.65 MPa (1.0 mbar–6.5 bar)
with dry leakage test in the pressure range from 22 hPa–0.3 MPa (22 mbar–3.0 bar)
The press connections are marked with a coloured dot. This identifies the SC‑Contur, where the test medium would escape in the case of an inadvertently unpressed connection.
The model is marked as follows:
flow direction indicator
noise class I on the basis of applicable regulations, see Regulations from section: Marking on components
dimension
DVGW writing
green dot for potable water
position indicator
The model is equipped with Raxofix press connections and compatible with the Raxofix system.
Raxofix plastic pipes are available as coiled bundle with and without protective pipe, and with various insulation thicknesses. Dimensionally stable multilayer pipes are also available in 5 m lengths. The following pipes are available:
Raxofix PE‑Xc/AI/Pe-Xc
dimensionally stable
with external oxygen seal coat
d 16, 20, 25
Raxofix PE‑Xc
flexible
without external oxygen seal coat
d 16, 20
Observe the following operating conditions for the installation of the model:
Operating temperature [Tmax] |
---|
Operating pressure [Pmax] |
70 °C |
1.0 MPa (10 bar) |
Overground pipelines and fittings in rooms do not normally require external corrosion protection.
There are exceptions in the following cases:
Contact with aggressive building materials such as nitrite or materials containing ammonium
Contact with aggressive chemicals
in aggressive surroundings
If external corrosion protection is required, observe the pertinent guidelines, see Regulations from section: Corrosion .
Easytop fittings made of gunmetal/silicon bronze are suitable for all types of potable water.
The chloride concentration in the medium must not exceed a maximum value of 250 mg/l.
This chloride is not a disinfectant, but in fact pertains to the content in sea and table salt (sodium chloride).
The following optional accessories are available:
Insulating shell
Equipment sets
Public building model
Mounting sets
Do not remove the model from the packaging until immediately before use.
System components may, in some cases, become damaged through transportation and storage.
Check all parts.
Replace damaged components.
Do not repair damaged components.
Contaminated components may not be installed.
Observe the following when mounting:
minimum / maximum installation depth
use suitable tools
Choose the place of installation so that the fitting is easily accessible, simple to operate and the insulating shell can be well mounted.
Information can be found in the Raxofix system instructions for use.
Information can be found in the Raxofix system instructions for use.
The following tools are required for production of a press connection:
Hand or electric saws or angle grinders are not permitted.
press machine with constant pressing force
suitable Raxofix press jaw for PE‑Xc systems
pipe shear (model 5341) for dimensions 16–25 mm
pipe cutters (model 2191) for dimensions 32–63 mm
bending tool (model 5331 or 5331.2)
Recommended Viega press machines:
Pressgun 5
Pressgun Picco
Pressgun 4E / 4B
Picco
Type PT3-AH
Type PT3-H / EH
Type 2 (PT2)
Leaky press connections due to damaged material!
Press connections can become leaky due to damaged pipes.
For information about tools, also see Required tools .
Cut the protective pipe to length using the protective pipe cutter (model 5341).
Cut the pipe to length using a pipe shear.
Make sure that the cut surface is clean and straight.
Cut the pipe to length using a pipe cutter (model 2191).
You will find information regarding the intervals in the Raxofix system instructions for use.
Push the pipe into the press connector until the pipe end is visible in the inspection window.
Check the insertion depth in the inspection window.
Open the press jaw and place at a right-angle onto the connector. Carry out the pressing process.
Connection is pressed.
Carry out a functionality test after initial mounting.
Installation is possible in masonry (wet construction) and in dry constructions (pre-wall / duct installations).
Attach the fitting from behind with the fixing set onto a Viega fitting holder with slot nuts.
Seal the wall lead-in on the front side of the wall with the self-adhesive sealing flange.
Attach the protective sleeve of the valve in front of and behind the cladding (e. g. sheetrock or Fermacell panels) with lock nuts.
Seal the wall lead-in on the front side of the wall with the self-adhesive sealing flange.
Open or close the valve with a ¼ turn.
During the preliminary building work phases:
Actuate the valve via the protective cap.
The installer must perform a leakage test before commissioning.
Carry out this test on a system that is finished but not yet covered.
Comply with the general rules of engineering and the applicable directives, see Regulations from section: Leakage test .
Document the result.
Inform your customer or the operator of the drinking water installation that the system has to be maintained on a regular basis.
Observe the applicable regulations for the operation and maintenance of drinking water installations, see Regulations from section: Maintenance .
Viega recommends actuating the fitting regularly and checking its function.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.